DOUBLE WALLED VERTICAL AUTOCLAVE

VERTICAL AUTOCLAVE (FULLY AUTOMATIC) “MAC” MSW-101(WN-FAD) DOUBLE WALLED VERTICAL AUTOCLAVE WITH WING NUT CLOSING LID

  • “MAC” Fully Automatic Vertical Autoclave are most ideal for critical applications requiring assured and reliable total destruction of all living micro-organisms.
  • These are fully automatic models requiring no human intervention till a full sterilization cycle is over.
  • An Ideal tool for Laboratories, hospitals, nursing homes, R & D labs etc.
  • Heaters cover stand and carrier/bucket are made of Stainless Steel.
  • With outer wall, inner chamber and lid made of stainless steel.
  • Lid is closed through WING NUT CLOSING ARRANGEMENT and is supplied with a stainless steel basket but fitted with drain valve and mains cord.
  • Mounted on mild steel support legs.
  • Lid is fitted with Pressure Gauge, Spring Loaded Safety Valve, Manual Exhaust Valve, Vacuum Breaker-cum-Purge Valve as a safety device and water level indicator.
  • Drain Valve facilitates easy cleaning of the chamber.
  • All internal joints are argon arc welded, ground and polished to give crevice free internals.
  • Operating range from 15 to 20 psi pressure (adjustable).
  • Audio visual alarm and heater cut off in case of low water for the safety of the heater elements.
  • Industrial grade energy efficient heaters reduce power bills drastically.
  • Accurate temperature control with user leve flexibility. Display process and set values simultaneously.
  • Microprocessor based automatically fuzzy logic control system with alphanumeric digital backlit LCD display.
  • Automatic steam purging and exhaust.
  • Fitted with AUTOMATIC DIGITAL MINUTE TIMER which starts automatically when set/desired value of temperature is achieved. When the set time period is over the heaters get switched off automatically with alarm for cycle end.
  • To work on 220/230Volts, 50/60 Hz AC supply.
Technical Specifications & Ordering Informations
MODEL #AVF-28(WN) #AVF-43(WN) #AVF-64(WN) #AVF-91(WN) #AVF-135(WN) #AVF-210(WN)
Inner Dimensions(Dia x Height) Ø250x450mm Ø300x500mm Ø350x550mm Ø400x600mm Ø450x710mm Ø550x760mm
Gross Capacity 28/22 ltrs. 43/40 ltrs. 64/53 ltrs. 91/78 ltrs. 135/113 ltrs. 210/187 ltrs.
Heater Load 2.0 KW 3.0 KW 3.0 KW 4.0 KW 4.0 KW 5.0 KW
Controller (PLC Based) µProcessor Based Fully Automatic Fuzzy Logic Control System
Display 16×2 line Alphanumeric Digital LCD with backlet display with Set Value (SV) and Process Value (PV)
Timer (Auto Time Control) & Buzzer Fitted with AUTOMATIC DIGITAL MINUTE TIMER which starts automatically when set/desired value of temperature is achieved. When the set time period is over the heaters get switched off automatically with alarm for cycle end.
Sterilizing Pressure 1.2 kgf /cm² (15 psi) at 121°C
Operating Pressure From 15 Psi to 20 Psi (Adjustable)
MOC (Pressure Vessel) Stainless Steel (SS-304)
MOC (External Wall) Stainless Steel
MOC (Top Lid) Thick machined Stainless Steel plate
Basket Stainless Steel (SS-304)
Power Supply 220/230V AC, 50/60Hz

VERTICAL AUTOCLAVE (SEMI AUTOMATIC DIGITAL) “MAC” MSW-101(WN-SAD) DOUBLE WALLED VERTICAL AUTOCLAVE WITH WING NUT CLOSING LID

  • “MAC”Semi Automatic Digital Autoclaves are most ideal for critical applications requiring assured and reliable total destruction of all living micro-organisms.
  • These are semi automatic models requiring tighter control of temperature and sterilizing time, thus eliminating any chances of under or over exposure of media/samples with respect to temperature and hold time.
  • An Ideal tool for Laboratories, hospitals, nursing homes, R & D labs etc.
  • Heaters cover stand and carrier/bucket are made of Stainless Steel.
  • With outer wall, inner chamber and lid made of stainless steel.
  • Lid is closed through WING NUT CLOSING ARRANGEMENT and is supplied with a stainless steel basket but fitted with drain valve and mains cord.
  • Mounted on mild steel support legs.
  • Lid is fitted with Pressure Gauge, Spring Loaded Safety Valve, Manual Exhaust Valve, Vacuum Breaker-cum-Purge Valve as a safety device and water level indicator.
  • Drain Valve facilitates easy cleaning of the chamber.
  • All internal joints are argon arc welded, ground and polished to give crevice free internals.
  • Operating range from 15 to 20 psi pressure (adjustable).
  • Moulded jointless silicon rubber gasket.
  • µProcessor based Controller with time and temperature programmable by user.
  • Class ‘A’ Platinum (Pt-100) sensor, enabling precise and accurate monitoring.
  • Low water level alarm and cut off for safety of heater.
  • Sensor open alarm and display.
  • End of cycle buzzer to alert the user and auto reset.
  • Miniature Circuit Breaker for MAINS On/Off plus safety of control panel.
  • Fitted with low-water level cut-off device.
  • Industrial grade energy efficient heaters reduce power bills drastically.
Technical Specifications & Ordering Informations
MODEL #AVS-28(WN) #AVS-43(WN) #AVS-64(WN) #AVS-91(WN) #AVS-135(WN) #AVS-210(WN)
Inner Dimensions(Dia x Height) Ø250x450mm Ø300x500mm Ø350x550mm Ø400x600mm Ø450x710mm Ø550x760mm
Gross Capacity 28/22 ltrs. 43/40 ltrs. 64/53 ltrs. 91/78 ltrs. 135/113 ltrs. 210/187 ltrs.
Heater Load 2.0 KW 3.0 KW 3.0 KW 4.0 KW 4.0 KW 5.0 KW
Controller Semi Automatic Digital temperature Indicator-cum-Controller
Display Digital LED with Set Value (SV) and Process Value (PV)
Timer (Auto Time Control) Fitted with AUTOMATIC DIGITAL MINUTE TIMER which starts automatically when set/desired value of temperature is achieved. When the set time period is over the heaters get switched off automatically
Sterilizing Pressure 1.2 kgf /cm² (15 psi) at 121°C
Operating Pressure From 15 Psi to 20 Psi (Adjustable)
MOC (Pressure Vessel) Stainless Steel (SS-304)
MOC (External Wall) Stainless Steel
MOC (Top Lid) Thick machined Stainless Steel plate
Basket Stainless Steel (SS-304)
Power Supply 220/230V AC, 50/60Hz